How to get immediate disconnect when using MVPs with Bogen TAM-B paging modules
There is an issue that comes about when using the MVPs with Bogen TAM-B paging modules where after the page is made several seconds of busy tone will be sent out the speaker. This can be stopped by setting the option called Calling Party Control Disconnect (CPC) on the Bogen with a time of 800ms.