Fixed - A configuration problem when using a computer with a USB to Serial converter.

ADDITIONAL INFORMATION:

Several problems may occur when using a USB to Serial converter:

- Can't access the VoIP with the configuration software.

- Can't save parameter changes.

- A Save / Reboot locks-up the VoIP.


Tested and recommended connectors:

Belkin, ioConcepts, Digicom


MVP2410 / MVP3010:
This was fixed in firmware version (4.07.c9) and corresponding software version (x.07).

MVP130:
This was fixed in firmware version (1.07.c9) and corresponding software version (x.07).

MVP210 / MVP410 / MVP810:
This was fixed in firmware version (6.07.c9) and corresponding software version (x.07).


The latest firmware and software along with instructions can be downloaded from our Web sites at:

http://www.multitech.com/en_US/SUPPORT/Families/MultiVOIP/firmware